Products
Steel Pedestrian Bridge & Skywalk

Product Category

Keep In Touch With Us

Steel Pedestrian Bridge & Skywalk

Steel pedestrian bridges and skywalks for campuses, transit hubs and links between buildings. We fabricate and trial-assemble each bridge in our shop and ship it in segments ready to lift.
Steel footbridge and skywalk fabricated in transportable segments, trial-assembled in the shop, with vibration comfort checks and C4 outdoor coating.

A footbridge is a structure that people walk on, so comfort matters as much as strength. A slender steel bridge can pass every strength check and still feel unacceptable because it vibrates under a walking crowd.

We fabricate footbridges and link bridges in segments, trial-assemble them in the shop, and design the coating system for the exposure class of the site.

Key Specifications

Span 20 – 80 m, single or multi-span
Section Welded box girder 600 – 2,000 mm, or truss 1.5 – 6 m deep
Vibration Vertical frequency < 5 Hz or lateral/torsional < 2.5 Hz requires a comfort check (EN 1990 Annex A2)
Comfort limits Vertical acceleration 0.7 m/s², lateral 0.2 m/s² (crowd 0.4 m/s²); walking frequency about 2 Hz
Coating C4 or C5 system: blast to Sa 2.5, zinc primer, epoxy intermediate, polyurethane topcoat
Erection Crane lift of complete spans, or incremental launching for over-road crossings

Vibration, the issue that decides the section

  • The natural frequency is set by mass and stiffness; a light steel bridge needs more depth or added mass (a concrete deck) to move out of the walking range.
  • Dampers can be added, but designing the frequency correctly is cheaper than tuning a damper after installation.
  • The comfort check follows EN 1990 Annex A2 for pedestrian bridges; the local code may set a different limit and governs.

Fabrication and trial assembly

  • Segments are trial-assembled in the shop and match-drilled, so the site bolted connection closes without reaming.
  • Pre-camber is built into the girder for dead load so the finished deck has the correct profile.
  • Bearings and expansion joints are set out to allow thermal movement without transferring force into the abutments.

Coating for outdoor service

Bridges are exposed to rain, de-icing salt and, near the coast, chloride. We specify a C4 system for inland sites and C5-M for coastal sites, with the total dry film thickness and the surface preparation recorded on the inspection sheet.

Span 20 – 80 m
Eave Height Truss depth 1.5 – 6 m
Structure truss
Main Material Q355B / Q390B welded box and H sections, C4 coating system
Application Pedestrian bridge, elevated walkway, link bridge between buildings, landscape walkway

What span can a steel pedestrian bridge have?

Spans are 20 to 80 m, single or multi-span. The section is a welded box girder 600 to 2,000 mm deep, or a truss 1.5 to 6 m deep.

How do you control bridge vibration?

A slender bridge can pass every strength check and still feel unacceptable because it vibrates under a walking crowd, so vibration is checked as part of the design. Walking frequency is about 2 Hz.

What comfort limits do you design to?

Vertical acceleration 0.7 m/s2 and lateral 0.2 m/s2, with 0.4 m/s2 for crowd loading.

How is the bridge delivered and protected?

It is fabricated in segments and trial-assembled in the shop. The coating is a C4 or C5 system, blasted to Sa 2.5 with zinc primer and epoxy intermediate, chosen for the exposure class of the site.