Steel Pedestrian Bridge & Skywalk
A footbridge is a structure that people walk on, so comfort matters as much as strength. A slender steel bridge can pass every strength check and still feel unacceptable because it vibrates under a walking crowd.
We fabricate footbridges and link bridges in segments, trial-assemble them in the shop, and design the coating system for the exposure class of the site.
Key Specifications
| Span | 20 – 80 m, single or multi-span |
| Section | Welded box girder 600 – 2,000 mm, or truss 1.5 – 6 m deep |
| Vibration | Vertical frequency < 5 Hz or lateral/torsional < 2.5 Hz requires a comfort check (EN 1990 Annex A2) |
| Comfort limits | Vertical acceleration 0.7 m/s², lateral 0.2 m/s² (crowd 0.4 m/s²); walking frequency about 2 Hz |
| Coating | C4 or C5 system: blast to Sa 2.5, zinc primer, epoxy intermediate, polyurethane topcoat |
| Erection | Crane lift of complete spans, or incremental launching for over-road crossings |
Vibration, the issue that decides the section
- The natural frequency is set by mass and stiffness; a light steel bridge needs more depth or added mass (a concrete deck) to move out of the walking range.
- Dampers can be added, but designing the frequency correctly is cheaper than tuning a damper after installation.
- The comfort check follows EN 1990 Annex A2 for pedestrian bridges; the local code may set a different limit and governs.
Fabrication and trial assembly
- Segments are trial-assembled in the shop and match-drilled, so the site bolted connection closes without reaming.
- Pre-camber is built into the girder for dead load so the finished deck has the correct profile.
- Bearings and expansion joints are set out to allow thermal movement without transferring force into the abutments.
Coating for outdoor service
Bridges are exposed to rain, de-icing salt and, near the coast, chloride. We specify a C4 system for inland sites and C5-M for coastal sites, with the total dry film thickness and the surface preparation recorded on the inspection sheet.
| Span | 20 – 80 m |
| Eave Height | Truss depth 1.5 – 6 m |
| Structure | truss |
| Main Material | Q355B / Q390B welded box and H sections, C4 coating system |
| Application | Pedestrian bridge, elevated walkway, link bridge between buildings, landscape walkway |
What span can a steel pedestrian bridge have?
Spans are 20 to 80 m, single or multi-span. The section is a welded box girder 600 to 2,000 mm deep, or a truss 1.5 to 6 m deep.
How do you control bridge vibration?
A slender bridge can pass every strength check and still feel unacceptable because it vibrates under a walking crowd, so vibration is checked as part of the design. Walking frequency is about 2 Hz.
What comfort limits do you design to?
Vertical acceleration 0.7 m/s2 and lateral 0.2 m/s2, with 0.4 m/s2 for crowd loading.
How is the bridge delivered and protected?
It is fabricated in segments and trial-assembled in the shop. The coating is a C4 or C5 system, blasted to Sa 2.5 with zinc primer and epoxy intermediate, chosen for the exposure class of the site.