Steel structure manufacturer since 2009 · 8 fabrication bases in China
Product Category
Keep In Touch With Us
Cold Storage Steel Building
A cold store is a steel frame wrapped in a thick insulated envelope. The frame itself is straightforward; what decides whether the building works is how the envelope, the floor insulation, the refrigeration pipework and the fire compartment walls meet the steel.
We select the steel grade by service temperature rather than quoting a fixed temperature limit: for −20 °C to −30 °C rooms the frame is normally Q355D or S355J2 with Charpy impact testing, and the bolts, welds and coating are specified to match.
Key Specifications
| Room temperature | −5 °C to −30 °C; lower on request with design review |
| Steel grade | Q355D / S355J2 impact-tested; Q355E for extreme service |
| Span | 18 – 36 m clear span, 8 – 12 m eave |
| Envelope | PIR or rock-wool sandwich panel 100 – 200 mm, vapour barrier on the warm side |
| Floor | Insulated floor slab with heater cables or glycol loop under the freezer |
| Fire | Compartment walls to the roof deck; steel protection matched to the fire strategy |
Thermal bridging is the real design problem
- Every steel member that crosses the insulation line becomes a cold bridge. Columns, roof purlins and the panel rails are detailed with thermal breaks or kept inside the warm envelope.
- Penetrations for refrigeration pipes, drains and door frames are sleeved and sealed with a vapour-tight detail, not simply foamed.
- The vapour barrier must be continuous on the warm side; a single gap in a freezer wall becomes an ice block within a season.
Fire strategy
Cold stores combine high fire load, insulated panels and long travel distances. The steel frame is protected by intumescent coating or board to the rating the fire consultant sets, and the panel core is selected to match — PIR for most food stores, rock wool where an A2 non-combustible core is required.
What we need to quote
Room temperatures and sizes, product type and stacking height, the refrigeration system, floor level and dock arrangement, and the fire rating required by the insurer or the local authority.
| Span | 18 – 36 m |
| Eave Height | 8 – 12 m |
| Structure | portal-frame |
| Main Material | Q355D / S355J2 impact-tested sections, stainless or hot-dip galvanized secondary members |
| Application | Frozen food storage, chilled distribution, pharmaceutical cold room |
What temperature range can the cold storage building handle?
Room temperature ranges from -5 C to -30 C. Lower temperatures are possible on request with design review.
Which steel grade is used for cold rooms?
We select the grade by service temperature. For rooms at -20 C to -30 C the frame is normally Q355D or S355J2 with Charpy impact testing, and Q355E is used for extreme service. Bolts, welds and coating are specified to match.
What decides whether a cold store works?
The frame itself is straightforward. What decides the result is how the insulated envelope, the floor insulation, the refrigeration pipework and the fire compartment walls meet the steel.
What clear span is available?
Clear spans are 18 to 36 m.